Trojan has led the development of water treatment solutions using environmentally friendly ultraviolet (UV) light. Trojan has the largest installed base of UV systems in operation on the planet, and many of their innovations define the industry standards for safeguarding your water from the damaging effects of microbial and chemical contamination.
Trojan UV Plus Monitored models offer an additional step of protection by adding a UV Intensity Sensor. This sensor monitors the amount of UV dosage that the water is getting. Allowing you to gauge whether your system is properly disinfecting your water. If the UV dosage is near the minimum acceptable level, the indicator light turns yellow telling you that you are near the minimum dosage recommended and should check your water quality and your lamp. If it drops below an acceptable level, the light turns red and an alarm sounds.
|
Ideal for average home sizes
- Does not affect taste, color and odor of the water
- Capable of destroying 99.9% of harmful microorganisms including: E. coli, Cryptosporidium and Giardia
- Easy to maintain
- Natural and safe disinfection without the use of harmful chemicals
- No disinfection by-products
- Fast acting
- Effective against a broader range of organisms than chlorine
- Best warranty on the market
|
- Confidence in Proper System Operation:
Indicator lights show the status of system components. Warning lights appear when system maintenance is required.
- Safety Cap and Special Lamp Plug:
The safety cap prevents children from accessing the lamp or electrical components. The special lamp plug ensures that no one can power the UV lamp if it is not in the UV chamber.
- Reference Card:
The reference card outlines the most important system functions and maintenance for your quick, on-the-spot questions.
- Lamp Age Display: A display will count down to indicate when the lamp should be replaced. When 30 days remain the lamp light will show yellow and alarm will sound giving you time to order your new lamp.
|
- UV Intensity Monitor
- Lamp Age Display and Alert
- Digital Diagnostic Display
- Alarm Reset Button
- Electropolished Exterior
|
| Additional Product Feature (Standard with models: G,H,J only) |
back to top |
- UV Intensity Monitor w/ CoolTouch Kit
The UV sensor is designed to detect a change in the UVT (Ultra Violet Transmittance) in the water. This will help make sure the UV is providing the necessary UV dose to inactivate the bacteria in the water.Note: If the UVT of the water falls below 75% that will send the system into alarm and "tripping" the solenoid valve stopping the flow of water to the house.
|
 |
- Solenoid Shut-off Valve
The Solenoid Valve will shut the water flow off if the system goes into alarm. This means that the water will not flow into the home if the UV is unable to disinfect the water.
Available upon checkout
|
 |
- COMM Center
COMM Center - for Plus Series systems, displays UV dose in real-time, alarm history, lamp hours, and other performance parameters for up to nine systems. Whether you are a testing lab or a business that needs to monitor the dosage in your water at any moment, the remote alarm CommCenter is the product for you. This powerful tool will allow you to monitor dosage, choose flow rate to monitor non-NSF units, computer tracking and much more.
Available upon checkout
|
 |
- UV Intensity Monitor w/ CoolTouch Kit (Optional for models: D,E,F)
All models come standard with UV Intensity Monitor, however the CoolTouch Kit is an option for models D, E and F
Available upon checkout
|
|
 UV light penetrates and permanently alters the DNA of the microorganisms in a process called thymine dimerization. The microorganisms are inactivated and rendered unable to reproduce or infect. Analogy: a broken zipper.
|
- Iron <0.3 PPM
- Hardness <120 PPM (7 GPG)
- UV Transmittance >75%
- Max Working Pressure 125 PSI
|
Disclaimer: The information on this website has not been reviewed by the FDA. Products offered for sale herein are not intended to treat, cure or prevent any disease or health condition. No medical claims are being made or implied. |
 |
Video Page
We invite you to watch the videos below to learn more about your water and how you can benefit from installing a Premium Pelican System in your own home. Pelican Water is the leader in premium whole house water filtration and salt-free systems. In this day and age it now more important than ever to filter your water, protect your pipes and appliances from the negative effects of hard water. |
|
| Is your water Safe? |
Learn about the problems we are facing today with our limited drinking water supply. Also learn about the Pelican solution for your family. Learn how chlorine and chloramines are absorbed through your skin and into your foods, including how to remove them from your water. Water is one of our most valuable resources and its time to start treating that way.
|
|
|
| Salt Water Softeners and Reverse Osmosis |
Learn about the affects of salt-based water softeners and how they work. Also learn about Reverse Osmosis (RO) systems and how they work. Many people who have a salt or potassium-based water softener do not realize the damaging effects it can have on our planet and our bodies over a period of time.
|
|
|
| Safeguarding your water |
Learn about the benefits and advantages of owning the Pelican Combo Series. The EPA says it is up to you to filter your water in your home. Adding a filter to your home is the first line of defense against harmful chemicals and byproducts. The Pelican Natursoft system offers a green alternative to water softening that will protect your biggest investment: your home, from scale and the damaging effects of hard water.
|
|
|
UV Max Manual (link opens in new window) |
| Models: D4 Plus, E4 Plus, F4 Plus |
|
UV Pro Manual (link opens in new window) |
| Models: G Plus, H Plus, J Plus |
General (All Models) |
Maximum Operating Pressure |
125 PSI (862 kPa) |
Minimum Operating Pressure |
4 PSI (27.5 kPa) |
Maximum Ambient Air Temperature |
122 F (50 C) |
Minimum Ambient Air Temperature |
32 F (0 C) |
Maximum Humidity |
100% |
Maximum Hardness |
120 PPM (7 Grains Per Gallon) |
Maximum Iron |
0.3 PPM |
| Minimum UVT |
75% |
| Installation |
Vertical or Horizontal * |
| * Systems with sensors must be installed vertically. |
|
 |
|
D4 Plus |
E4 Plus |
F4 Plus |
G Plus |
H Plus |
J Plus |
No-tools Maintenance |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Safety Cap & Special Lamp Plug |
Yes |
Yes |
Yes |
-- |
-- |
-- |
| Lamp Operation Indicator |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Power Supply Operation Indicator |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Sensor Operation Indicator |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Sensor w/ Diagnostic Test |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Reference Card |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Lamp Timer Display |
Yes |
Yes |
Yes |
-- |
-- |
-- |
| Lamp Timer Reset Button |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Mute Button |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Solenoid Valve |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
| External Control Relay |
Optional |
Optional |
Optional |
Optional |
Optional |
Optional |
|
D4 Plus |
E4 Plus |
F4 Plus |
G Plus |
H Plus |
J Plus |
Flow Rates
|
Maximum rated flow at dose of 16 mJ/cm2 |
16 GPM
(60 LPM) |
29 GPM
(110 LPM) |
45 GPM
(170 LPM) |
-- |
-- |
-- |
| Maximum rated flow at dose of 30 mJ/cm2 |
9 GPM
(34 LPM) |
15 GPM
(57 LPM) |
25 GPM
(95 LPM) |
up to 19 GPM (72 LPM) |
20-39 GPM (76-148 LMP) |
40-45* GPM (151-170 LPM) |
| Maximum rated flow at dose of 40 m/J/cm2 |
7 GPM
(26 LPM) |
12 GPM
(45 LPM) |
20 GPM
(76 LPM) |
up to 15 GPM (57 LPM) |
16-29 GPM (61-110 LPM) |
30-44 GPM (114-167 LPM) |
| Electrical |
| Voltage |
100-240V AC |
100-240V AC |
100-240V AC |
100-240V AC |
100-240V AC |
100-240V AC |
| Frequency |
50-60 Hz |
50-60 Hz |
50-60 Hz |
50-60 Hz |
50-60 Hz |
50-60 Hz |
| Max. Current |
.05 Amp |
.85 Amp |
1.2 Amp |
1.2 Amp |
1.6 Amp |
2.4 Amp |
| Max Power Consumption |
50 Watts |
83 Watts |
130 Watts |
120 Watts |
160 Watts |
230 Watts |
| Lamp Power |
40 Watts |
70 Watts |
110 Watts |
100 Watts |
140 Watts |
200 Watts |
| Other |
| UV Chamber Material |
304 SST |
316 SST |
316 SST |
316 SST |
316 SST |
316 SST |
| Inlet/Outlet |
3/4" |
1" |
1" |
Combo
1 1/4" NPT,
1" FNPT |
Combo
1 1/4" NPT,
1" FNPT |
Combo
1 1/4" NPT,
1" FNPT |
| Lamp Life |
1 Year |
1 Year |
1 Year |
2 Years |
2 Years |
2 Years |
Flow rates shown are at 85% UVT and End of Lamp Life
*Inlet/outlet size restricts flow to 45 GPM and the dose will be 39mJ/cm2
|
The TrojanUVMax™ comes with a full, non-prorated 3-year warranty against manufacturer's defects on the power supply and all electrical components; a 10-year guarantee on the UV chamber; and a 1-year warranty on lamps and sensors.
The TrojanUVMax™ G, G Plus, H, H Plus, J, J Plus come with a full 5-year warranty against manufacturer's defects on the power supply and all electrical components; a 10-year guarantee on the UV chamber; and a 1-year warranty on lamps and sensors.
Note: Manufacturer's warranty and performance guarantees do not cover acts of God, misuse or abuse. All products must be used in accordance to the specific application. All warranties and performance guarantees are valid to the original purchases and purchaser's delivery location. Labor and/or cost of damage due to misuse or defective items are the responsibility of the purchaser. If you have not had a water test done before purchasing a system, a certified water test may be required for any warranty claims. Should your water test show contaminants unknown at the time of purchase or unknown to Pelican, this may void your warranty. Please contact your authorized Pelican Dealer for further details. Enviro Water Solutions, Inc. or its Authorized Dealers will not be liable for any circumstance for consequential or incidental damages. It is the purchaser's responsibility to ensure that the equipment is installed in compliance with all applicable building codes.
|
| Q. What does the D4 Plus model have that this one does not? |
When you purchase a Plus model UV system, you are getting the same great UV disinfection the normal model has, but with added peace of mind and security. All Plus models include the lamp-age display and alarm system w/reset button. They also include a UV intensity monitor, which is used to keep a close eye on the amount of UV you are getting into your water.
This monitor is required in some states when installing a UV (contact your water company or building inspector) and will ensure that you are getting proper disinfection. If the UV intensity begins to drop, then you know its time to clean the sleeve or replace the lamp.
|
| Q. Is there a lot of maintenance required with a UV system? |
All you have to do is periodically clean the lamp sleeve and replace your lamp once a year - simple processes you can complete in minutes. For ease of handling the lamp and protective quartz sleeve are designed as one component, but can be replaced separately. No tools are required for maintenance.
|
| Q. What type of warranty do the Trojan UV Max Systems come with? |
The Trojan UV Max comes with a full five year warranty against manufacturer's defects on the power supply and all electrical components; a ten year guarantee on the water chamber; and a one year warranty on lamps and UV intensity monitors.
|
| Q. Why is it recommended to pretreat the water before installing a Trojan UV Max System? |
A 5-micron sediment pre-filter is recommended to remove dirt and debris. The reason for this pretreatment is the quality of the water can not only affect the dosage of UV disinfection the system provides, it may also cause premature "sleeve fouling" which will require the sleeve to be cleaned more often, and may also damage the UV sleeve.
|
| Q. What makes the Trojan UV Max light more effective than other on the market? |
The UV light is generated from a low-pressure, high-output lamp new to the residential and commercial UV market. These lamps provide a higher intensity of UV light making it possible to treat a given volume of water with smaller, more efficient units.
|
|